Remote Monitoring & Management Help

Synology Fan Status Check

The Fan Status (Synology) Check monitors the status of the fans on a Synology device.

Basic Check information

Check Type SNMP
Supported Systems/Application SNMP-enabled devices that support the Synology MIB
Supported Device Class Storage

Troubleshooting

Issue Corrective Action
Failed Please check that the correct SNMP community string is configured in Network Discovery for the device
201 Exception OID_TYPE_NOSUCHOBJECT Missing OID object on the device for specific metric

Metrics

Name Default Thresholds
System Fan Status

Normal: 1

Failed: 2

System Fan Status Description

No Thresholds

CPU Fan Status

Normal: 1

Failed: 2

CPU Fan Status Description No Thresholds

SNMP Properties Queried

Variable Name SNMP OID
systemFan 1.3.6.1.4.1.6574.1.4.1
cpuFan 1.3.6.1.4.1.6574.1.4.2

Calculations Performed

Variable Name Calculation
System Fan Status systemFan
System Fan Status Description

systemFan value mapped:

1 to Normal

2 to Failed

CPU Fan Status cpuFan
CPU Fan Status Description

cpuFan value mapped:

1 to Normal

2 to Failed