N-central Help

Battery Status (NetApp) service

The Battery Status (NetApp) service monitors the health of the NVRAM battery in a NetApp SAN.

Basic service information

Service Type SNMP
Supported Systems/Application Any NetApp device with SNMP enabled.
Max Instances on each device 1
Supported Device class Switch/Router, other
Monitored by Windows probe

Troubleshooting

Issue Corrective Action
Misconfigured

Check the following:

  • You have the correct SNMP community string specified for the device.
  • The correct SNMP index has been specified on the Service Details tab (the correct SNMP index can be found by querying the NetApp SAN with the 1.3.6.1.4.1.789.1.2.5.1 SNMP OID)

Metrics

Name OID Used Default Thresholds
Battery Status 1.3.6.1.4.1.789.1.2.5.1

Normal: 1 (ok)

Warning: Partially Discharged (2), Near End of Life (5)

Failed: Fully Discharged (3), Not Present (4), At End of Life (6), Unknown (7)