N-central Help

Temperature Status (Fujitsu) service

The Power Supply (Fujitsu) service monitors the status of a temperature sensor in a Fujitsu device.

Service Type SNMP
Instances on a Device 100
Supported Systems/Applications Fujitsu servers running the Fujitsu ServerView agent.
Device Class for CPU (SNMP) Servers - Generic or Servers - Windows
Monitored By Windows agent
Power Supply Enter the name of the monitored temperature sensor. For a list of temperature sensors, query the device with the .1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.4 SNMP OID.
Scanning You can configure the scan interval according to either a Once a Day or Daily Interval schedule.

 

Object Descriptors Numerical OID
$Status 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.5
$CurrentTemperature 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6
$WarningLevel 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.7
$CriticalLevel 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.8
$CriticalReaction

1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.9

 

Status Detail Description
Status

Describes the current status of the monitored temperature sensor t with values mapped as:

  1. WARNING - Unknown
  2. NORMAL - Not Available
  3. NORMAL - OK
  4. FAILED - Sensor Failed
  5. FAILED - Failed
  6. WARNING - Temperature Warning – Too Hot
  7. FAILED - Temperature – Critical
  8. NORMAL - Temperature – Normal
  9. WARNING - Temperature Warning