N-central Help

RAID Controller Status (Fujitsu) service

The RAID Controller Status (Fujitsu) service monitors various elements of a RAID Controller in a Fujitsu device.

Service Type SNMP
Instances on a Device 100
Supported Systems/Applications Fujitsu servers running the Fujitsu ServerView agent.
Device Class for CPU (SNMP) Servers - Generic or Servers - Windows
Monitored By Windows agent
RAID Contoller Enter the name of the monitored RAID controller. For a list of RAID controllers, query the device with the .1.3.6.1.4.1.231.2.49.1.4.2.1.25 SNMP OID.
Scanning You can configure the scan interval according to either a Once a Day or Daily Interval schedule.

 

Object Descriptors Numerical OID
$Manufacturer 1.3.6.1.4.1.231.2.49.1.4.2.1.3
$Model 1.3.6.1.4.1.231.2.49.1.4.2.1.2
$BusLocation 1.3.6.1.4.1.231.2.49.1.4.2.1.5
$FirmwareRevision 1.3.6.1.4.1.231.2.49.1.4.2.1.7
$BIOSRevision 1.3.6.1.4.1.231.2.49.1.4.2.1.8
$NumberOfChannels 1.3.6.1.4.1.231.2.49.1.4.2.1.9
$NumberOfPhysicalDisks 1.3.6.1.4.1.231.2.49.1.4.2.1.11
$NumberOfLogicalDrives 1.3.6.1.4.1.231.2.49.1.4.2.1.12
$CacheSize 1.3.6.1.4.1.231.2.49.1.4.2.1.13
$Status 1.3.6.1.4.1.231.2.49.1.4.2.1.15
$Interface 1.3.6.1.4.1.231.2.49.1.4.2.1.16
$SerialNumber 1.3.6.1.4.1.231.2.49.1.4.2.1.21
$DriverName 1.3.6.1.4.1.231.2.49.1.4.2.1.22
$DriverRevision 1.3.6.1.4.1.231.2.49.1.4.2.1.23
$BBUSStatus 1.3.6.1.4.1.231.2.49.1.4.2.1.24
$UEFIDriverRevision 1.3.6.1.4.1.231.2.49.1.4.2.1.27

 

Status Detail Description
Controller Status

Describes the current status of the monitored RAID controller with values mapped as:

  1. NORMAL - OK
  2. WARNING - Warning
  3. FAILED - Error
  4. WARNING - Unknown
Battery Backup Status

Describes the current status of the backup battery for the monitored RAID controller with values mapped as:

  1. WARNING - Unknown
  2. NORMAL - Not Installed
  3. NORMAL - Normal
  4. WARNING - Charging
  5. WARNING - Discharging
  6. WARNING - Warning
  7. FAILED - Failed
Manufacturer The name of the manufacturer of the RAID controller.
Model The model (descriptive name) of the RAID controller.
Serial Number The serial number of the RAID controller.
Firmware Version The version of the RAID controller firmware.
BIOS Version The version of the BIOS of the monitored RAID controller.
UEFI Version The version of the UEFI (Unified Extensible Firmware Interface) of the monitored RAID controller.
Driver Name The name of the software driver for the monitored RAID controller.
Driver Version The version of the software driver for the monitored RAID controller.
Bus Location The location of the bus interface for the RAID controller that is being monitored.
Number of Channels The number of hard disk channels available for the monitored RAID controller.
Number of Physical Disks The total number of installed physical disks in the array.
Number of Logical Drives The total number of installed logical disks in the array.
Onboard Cache Size The size in megabytes, of the onboard cache within the array.
Disk Connection Interface The type of disk interface of the monitored RAID controller, for example, IDE, SCSI, or SAS.