N-central Help

Temperature Status (EqualLogic) service

The Temperature Status (EqualLogic) service monitors the temperature of a Model PS6100 Dell EqualLogic SAN running v6.0.2 firmware.

Service Type SNMP
Instances on a Device 1
Supported Systems/Applications Model PS6100 Dell EqualLogic SAN running v6.0.2 firmware.
Device Class Server - Generic, Server - Windows
Monitored By Windows agent
Scan Interval 5 minutes
Temperature Sensor Enter the name of the temperature sensor to monitor. For a list of temperature sensors, query the SAN with the .1.3.6.1.4.1.12740.2.1.6.1.2 SNMP OID.

 

Object Descriptors Numerical OID
$Temperature 1.3.6.1.4.1.12740.2.1.6.1.3
$SensorState 1.3.6.1.4.1.12740.2.1.6.1.4

 

Status Detail Description
Temperature (°C) The current temperature reading.
Sensor State

The temperature sensor status is mapped as:

  • Normal = 1
  • Warning = 2, 0
  • Failed = 3
Sensor State Description

Description of the status of the temperature sensor:

  • 0 = Unknown
  • 1 = Normal
  • 2 = Warning
  • 3 = Critical