N-central Help

Temperature Probe (Dell iDRAC) service

The Temperature Probe (Dell iDRAC) service monitors the status of a temperature sensor on a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service Type SNMP
Instances on a Device 100
Supported Systems/Applications Dell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC).
Device Class for CPU (SNMP) Servers - Management Interface
Monitored By Windows agent
Scan Interval 5 minutes
SNMP Value Enter or select the name of the temperature sensor to monitor.

$#160;

Status Detail Object Descriptors Numerical OID Description
Location Name $LocationName 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 The location name of the temperature probe.
Settings $Setting 1.3.6.1.4.1.674.10892.5.4.700.20.1.4

The state settings of the temperature probe mapped as:

1 - unknown
2 - enabled
4 - notReady
6 - enabledAndNotReady

Status $Status 1.3.6.1.4.1.674.10892.5.4.700.20.1.5

The current status of the temperature sensor mapped as:

1 - other
2 - unknown
3 - ok
4 - nonCriticalUpper
5 - criticalUpper
6 - nonRecoverableUpper
7 - nonCriticalLower
8 - criticalLower
9 - nonRecoverableLower
10 - failed