N-central Help

Network Card (Dell iDRAC) service

The Network Card (Dell iDRAC) service monitors the status of specified Network Interface Controllers (NICs) on a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service Type SNMP
Instances on a Device 100
Supported Systems/Applications Dell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC).
Device Class for CPU (SNMP) Servers - Management Interface
Monitored By Windows agent
Scan Interval 15 minutes
SNMP Value Enter or select the name of the network device to monitor in the format NetworkDevice FQDD (Fully Qualified Device Descriptor). For a list of network devices, query the device with the .1.3.6.1.4.1.674.10892.5.4.1100.90.1.30 SNMP OID.

Status Detail Object Descriptors Numerical OID Description
Product Name $Name 1.3.6.1.4.1.674.10892.5.4.1100.90.1.6 The product name of the network device.
MAC Address $MacAddress 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15 The current MAC address of the network device.
Connection Status $ConnectionStatus 1.3.6.1.4.1.674.10892.5.4.1100.90.1.4

The current connection status of the network device mapped as:

1 - connected
2 - disconnected
3 - driverBad
4 - driverDisabled
10 - hardwareInitalizing
11 - hardwareResetting
12 - hardwareClosing
13 - hardwareNotReady

Status $Status 1.3.6.1.4.1.674.10892.5.4.1100.90.1.3

The current status of the network device mapped as:

1 - other,
2 - unknown,
3 - ok,
4 - nonCritical,
5 - critical, and,
6 - nonRecoverable.