N-central Help

Chassis Intrusion (Dell iDRAC) service

The Chassis Intrusion (Dell iDRAC) service monitors the chassis security feature that detects if a chassis component is removed or replaced from a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service Type SNMP
Instances on a Device 100
Supported Systems/Applications Dell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC)
Device Class for CPU (SNMP) Servers - Management Interface
Monitored By Windows agent
Scan Interval 15 minutes
SNMP Index Enter or select the name of the SNMP index to be used by this service.

Status Detail >Object Descriptors Numerical OID Description
Status $Status 1.3.6.1.4.1.674.10892.5.4.300.70.1.5

The current status of the chassis intrusion sensor mapped as:

1 - other,
2 - unknown,
3 - ok,
4 - nonCritical,
5 - critical, and,
6 - nonRecoverable.

Reading $Reading 1.3.6.1.4.1.674.10892.5.4.300.70.1.6

Indicates whether or not the chassis intrusion sensor is currently being read mapped as:

1 - chassisNotBreached,
2 - chassisBreached,
3 - chassisBreachedPrior, and,
4 - chassisBreachSensorFailure.

Type $Type 1.3.6.1.4.1.674.10892.5.4.300.70.1.7

Indicates the type of the intrusion sensor used for chassis security mapped as:

1 - chassisBreachDetectionWhenPowerON, and,
2 - chassisBreachDetectionWhenPowerOFF.

Settings $Setting 1.3.6.1.4.1.674.10892.5.4.300.70.1.4

Indicates the current state settings of the intrusion sensor mapped as:

1 - unknown,
2 - enabled,
4 - notReady, and
6 - enabledAndNotReady.